Hard-wired High Security Networked IR Barrier
MODULARITTY : Two different housings to adapt to different site configurations
INNOVATION : ZONING function, TCP/IP network for remote set-up and maintenance
ADAPTABILITY : Single or double face; Single or dual direction; Adaptable column heights
Overview
The MAXIRIS 3000/3100 infrared barriers deliver the highest level of performance in invisible/virtual fence systems from PROTECH. For perimeters longer than .6 miles (or 1 km), the MAXIRIS 3000/3100 columns can be directly connected to a TCP/IP network or RS485 bus via the MAXIBUS 3000 Hub.
The MAXIRIS ZONING function enables up to three virtual detection zones per barrier/ system that can be configured accordingly, allowing for video verification based on alarms by zone.
Each barrier is self-contained with a multi-lingual HTML server integrated into each column (English, French, Spanish, etc.).
System configuration and maintenance operations can be handled remotely.
MAXIRIS 3000
- Single face column
- Up to 36 beams per column and per direction
- Zoning function: 4 to 10 cells per column
MAXIRIS 3100
- Single and double face column
- High-density beams: up to 64 beams per two-direction column
- Zoning function: minimum of 4 to maximum of 10 cells per column
- Zoning function: 4 to 10 cells per column
The MAXIRIS technology and housing allow it to be installed on a wide variety of sites:
- logistics sites,
- particularly sensitive sites: prisons, nuclear power plants, military sites, etc.
- public places: airports, metros, etc.
- industrial sites, etc.
MAXIRIS 3000 | MAXIRIS 3100 | |
Maximum interior range | 1,640 ft./500 m | 1,640 ft./500 m |
Maximum exterior range at all times | 3,200 ft./100 m | 3,200 ft./100 m |
Column height | 3.6 ft. 1.1 m - 6.5 ft. 2 m - 8 ft. 2.5 m - 10 ft. 3 m - 12.5 ft. 3.8 m | 3.2 ft. 1 m - 6.5 ft. 2 m - 8 ft. 2.5 m - 10 ft. 3 m |
Intrusion alarm information | Up to three intrusion areas with distance from each configurable area | Up to three intrusion areas with distance from each configurable area |
Alarms provided | Intrusion (up to 3 zones), Disqualification, Tamper, Anti-climbing, Technical default | Intrusion (up to 3 zones), Disqualification, Tamper, Anti-climbing, Technical default |
Alarm outputs | RS 485 on each MAXIBUS 3000 compatible column Ethernet (RJ45 on each column) compatible with ModBus TCP server/client Dry contact outputs: 2 relays (NO) per column (configurable assignment) | RS 485 on each MAXIBUS 3000 compatible column Ethernet (RJ45 on each column) compatible with ModBus TCP server/client Dry contact outputs: 2 relays (NO) per column (configurable assignment) |
Power supply | 110 Vac/230 Vac - 60 Hz/50Hz | 110 Vac/230 Vac - 60 Hz/50Hz |
Alignment aid tools | Audible and visual signals on all the columns | Audible and visual signals on all the columns |
Operating Temperature | -40°F to+158°F (-40°C to+70°C) thermostat-controlled heater on each column | -40°F to+158°F (-40°C to+70°C) thermostat-controlled heater on each column |
Electromagnetic compatibility | Compliant with European standards (EC label) | Compliant with European standards (EC label) |
Configuration tools | HTML server integrated into each column (local access) | HTML server integrated into each column (local access) |
HTML server functions | • Password protected • Read/writing of parameters • Log and real-time infrared-beam status display | • Password protected • Read/writing of parameters • Log and real-time infrared-beam status display |
Ensure barrier is installed on a stable support (not mesh, unstable pole, etc.).
Ensure ground is level to ensure stability of the columns over time. A maximum of 10° elevation will be tolerated between the columns. In elevations above 10°, contact PROTECH’s sales department.
Ensure site is free from vegetation that could cover the beams, regardless of the season / weather.
Check the cleanliness of the covers. Recommended to clean with a soft and damp cloth at least annually.
Infrared technology operates at a wavelength above that of visible light (950nm), which makes the IR beam invisible to the naked eye.
IR beams are transmitted and received by infrared cells – transmitter cells generate and send a pulsed beam to the receiver cells which capture infrared pulses and turn them into electrical signals. When an absence, loss or change in the signal occurs (loss of 95% of the transmitted signal), an intrusion alarm is triggered. To prevent interference of receiver cells by the infrared beams being transmitted, cells are multiplexed.
Multiplexing is a principal whereby infrared pulses are transmitted in a synchronized manner by an optical or wired link between transmitter and receiver columns. This feature optimizes cell alignment (“alignment feedback”). All the PROTECH IR barriers are multiplexed (except BIRIS II).